It is possible traslate this to KOP ? Thank you.Код:
UN T 0 U E 33.5 S M 10.1 U M 10.1 = A 32.0 UN E 33.1 S M 10.2 U M 10.2 = A 32.1 U M 1.2 O M 100.0 R M 10.2 R M 10.1 UN M 10.1 UN M 10.2 UN M 20.0 UN M 20.1 = A 32.6 U M 20.1 = A 33.4 U M 20.0 = A 32.2 U E 33.2 O E 33.4 O E 32.7 O M 100.0 = A 32.7 U E 32.7 O E 33.4 O E 33.2 UN M 10.0 = M 1.2 U E 32.7 O E 33.4 O E 33.2 = M 10.0 BE
Answers to FAQs Март 29, 2022 3:03
like thisShowКод:
// net1 UN T 0 U E 33.5 S M 10.1 // net2 U M 10.1 = A 32.0 // net3 UN E 33.1 S M 10.2 // net4 U M 10.2 = A 32.1 // net5 U M 1.2 O M 100.0 R M 10.2 R M 10.1 // net6 UN M 10.1 UN M 10.2 UN M 20.0 UN M 20.1 = A 32.6 // net7 U M 20.1 = A 33.4 // net8 U M 20.0 = A 32.2 // net9 U E 33.2 O E 33.4 O E 32.7 O M 100.0 = A 32.7 // net10 U E 32.7 O E 33.4 O E 33.2 UN M 10.0 = M 1.2 // net11 U E 32.7 O E 33.4 O E 33.2 = M 10.0 // net12 BE
write all section into separate network & change view awl->,kor
gtvpic Март 29, 2022 5:52
In STEP5 it is not possible in LAD to have more than one coil in the same segment, in the sent code there is more than one coil in the same segment, therefore it is not possible to represent it in LAD
The solution is to copy the code of each of the Coils in a separate segment and place the ‘NOP 0 ‘ instructions necessary for the STEP5 to perform the conversion from STL to LAD.
Seeing how simple the code is, it is preferable to translate it directly in the STEP5 proprio to KOP instead of copying and revising
-